Remove a module
Perform these tasks if you need to remove an SFP or XFP module.
Task
1
Disconnect the network fiber-optic cable from the module.
2
Release the module from the slot by pulling the bail clasp out of its locked position.
3
Slide the module out of the slot.
4
Insert the module plug into the module optical bore for protection.
Power on the Sensor
Before you begin
Do not attempt to power on the Sensor until you have installed the Sensor in a rack, made
all necessary network connections, and connected the power cable to the power supply.
If you are installing a redundant power supply, you should install it as described in Installing a power
supply. For true redundant operation with the optional redundant power supply, McAfee recommends
that you plug each supply into a different power circuit.
Task
1
Connect the power cable to the Sensor power supply.
2
Connect the power cable to a power source.
The Sensor has no power switch. It powers on as soon as one of its power cable is connected to a
power source.
Power off the Sensor
McAfee recommends that you use the shutdown CLI command to halt the Sensor before powering it
down. For more information on CLI commands, see McAfee Network Security Platform CLI Guide.
Setting up the Sensor
Power on the Sensor
3
McAfee
®
Network Security Platform M-3050/M-4050 Sensor Product Guide
25
Comentarios a estos manuales